Share
Reference: N/A

Choisissez votre modèle :

ACT-1000N - Motorized crimp test bench
ACT-1000-V300 motorized crimping tester

How do realize a crimping control

Crimp control by image analysis

One of normalize method consist to make  a cut of the podset to make a aspect control and image analysis dimmensionnel.  In general cutting is done with a metallographic and the pod is then observed with a triancular adapted to a camera and dedicated software.

Control by traction force with motorized test stand

The lugs is placed in a « puller » band the wire is clamped to the moving part of test bench. The movement can be either motorized or manual. With a motorized test bench like the  ACT1000N, you can perform 2 types of test. Either a BREAK, where the force is exerted  gradualy until failure, or a KEAP, where a predifined  force is a exerted  for a set time.

Motorized test bench traction force for control of terminal crimping and crimped cable.

Traction motirized bench for crimp test ACT1000 N special create for the quality verification of crimping your terminals.

  • TEST°1: Pull-off or breakage test to evaluate the tensile force on electrical wires and accurately determine the value leading to sample breakage.
  • TEST°2: Maintain force test for a set period of time.

Once the test has been completed, the moving part automatically returns to its original position, and the tester saves the result in its internal memory and on the PC.

It is possible to configure 26 saved tests from A to Z. Once the test has been set up, simply press the START button to start the automatic test cycle.

When the test is completed, the carriage returns to its initial position, and the value appears on the display, along with the test information OK or NG (No good).

The results is stored in the test bench memory and/or on the PC, if the instrument is connected to the ACT LOGGER software.

ACT 100 N can be set from the test bench menu and also from the software. ACT-LOGGER software, makes it easy to ensure production exellent production traceability.

It enables results to be collected and archived them in folders or CSV files, which can be read in EXCEL, as wel as the printing of an inspection report.

The mesurement are realised at 2000Hz sampling frequency a enabling a precision ± 0,5%.

The BREAK and KEEP mode are selectable on the BREAK mode , you can do a destructifs non destructif test for applying a specifc force on a predefined times.

 

 

ACT-1000N ACT-1000N- V300

Model

Range

Reading

accuracy

Sampling frequency

Permissible Overload

Speed

Mouvement

Maxi Sample lengh

1000 N

1N

±0,5% FS ±1 Digit

2000 Hz

150% FS

10/25/50/100 mm/min

50 mm

100 mm

1000 N

1N

±0,5% FS ±1 Digit

2000 Hz

150% FS

25/50/100/300 mm/min

50 mm

100 mm